Add to Cart
Home Appliances Residential on-off and Inverter R410A Split Air Conditioner
Product Features:
1: World famouns brand rotary type compressor;
2: High Efficient Internal Thread Copper pipe for condensor and evaporator;
3: LED digital display, Best Visibility
4: Self-diagnose capability, error code showing for detection convenience;
5: Intelligent Defrost, Independent Dehumidification, Sleep Mode, Quiet Operation;
6: Low Voltage Startup, Auto-protection, Auto Restart;
7: Optional Refrigerant: R410A & R22;
8: Optional Voltage: 220V/50Hz & 220V/60Hz;
Reverse Cycle Fixed Speed Models Specifications | |||||||
Model | 7K | 9k | 12k | 12k | 18k | ||
GSC-07HA | GSC-09HA | GSC-12HA/A | GSC-12HA/B | GSC-18HA | |||
Type | heating pump | heating pump | heating pump | heating pump | heating pump | ||
Control type | remote | remote | remote | remote | remote | ||
Rated cooling capacity | Btu/h;W | 7000;2050 | 9000;2640 | 12000;3520 | 12000;3520 | 18000;5280 | |
Rated heating capacity | Btu/h;W | 7500;2200 | 9500;2800 | 12500;3700 | 12500;3700 | 18500;5420 | |
EER for cooling | W/W | 10.98;3.22 | 10.98;3.22 | 10.95;3.21 | 10.95;3.21 | 11.02;3.23 | |
Class in Cooling | A | A | A | A | A | ||
COP for heating | W/W | 3.61 | 3.61 | 3.62 | 3.62 | 3.61 | |
Class in Heating | A | A | A | A | A | ||
Moisture removal | Liters/h | 0.8 | 1 | 1.2 | 1.2 | 2 | |
Pressure | High(DP) | MPa | 4.5 | 4.5 | 4.5 | 4.5 | 4.5 |
Low(SP) | MPa | 1.9 | 1.9 | 1.9 | 1.9 | 1.9 | |
Indoor noise level(S/H/M/L/Mute) | dB(A) | 35/33/29/27/25 | 35/33/29/27/25 | 43/40/37/33/31 | 43/40/37/33/31 | 43/40/38/37/37 | |
Outdoor noise level | dB(A) | 50 | 50 | 52 | 52 | 55 | |
Electrical Data | |||||||
Power supply | 220-240V~/50Hz/1P | 220-240V~/50Hz/1P | 220-240V~/50Hz/1P | 220-240V~/50Hz/1P | 220-240V~/50Hz/1P | ||
Voltage Range | V | 198~264 | 198~264 | 198~264 | 198~264 | 198~264 | |
Rated current | Cooling | A | 2.95 | 3.8 | 5.1 | 5.1 | 7.6 |
Heating | A | 2.83 | 3.6 | 4.7 | 4.7 | 7 | |
Rated input | Cooling | W | 640 | 820 | 1100 | 1100 | 1640 |
Heating | W | 610 | 775 | 1020 | 1020 | 1500 | |
Annual energy consumption(cooling) | kwh | 350 | 410 | 550 | 550 | 820 | |
Max Current | Cooling | A | 4.6 | 4.9 | 6.6 | 6.6 | 9.9 |
Heating | A | 4.6 | 4.9 | 6.6 | 6.6 | 9.1 | |
Max Power input | Cooling | W | 1000 | 1060 | 1430 | 1430 | 2130 |
Heating | W | 1000 | 1060 | 1430 | 1430 | 2130 | |
Refrigerating&Fan System | |||||||
Refrigerant/Charge | kg | R410A/0.380 | R410A/0.420 | R410A/0.630 | R410A/0.630 | R410A/0.930 | |
Compressor | Type | ASN82V1UDZ | ASN86V1UDZ | ASM135V1VDZ | ASM135V1VDZ | PA190M2AS-4KUL1 | |
Model | GMCC | GMCC | GMCC | GMCC | GMCC | ||
Brand | Rotary | Rotary | Rotary | Rotary | Rotary | ||
Expansion device | Capillary tube | Capillary tube | Capillary tube | Capillary tube | Capillary tube | ||
Indoor air circulation(Cooling/Heating) | m3/h | 560 | 560 | 650 | 650 | 1100 | |
Indoor fan motor | type | Cross flow | Cross flow | Cross flow | Cross flow | Cross flow | |
Output | W | 13 | 13 | 21 | 21 | 25 | |
Capacitor | uF | 1.2 | 1.2 | 1.5 | 1.5 | 1.5 | |
Indoor fan speed H/M/L | Cooling | rpm | 125011501050950900 | 125011501050950900 | 125011501050950900 | 125011501050950900 | 125011501050950900 |
Heating | rpm | 125011501050950900 | 125011501050950900 | 125011501050950900 | 125011501050950900 | 125011501050950900 | |
Dry | rpm | 900 | 900 | 900 | 900 | 900 | |
Sleep | rpm | 900 | 900 | 900 | 900 | 900 | |
Evaporator | a.Number of rows | 1 | 1 | 2 | 2 | 2 | |
b.Fin spacing | mm | 1.3 | 1.3 | 1.4 | 1.4 | 1.4 | |
c.Tube outside dia.and type | mm | Φ7,innergroove tube | Φ7,innergroove tube | Φ7,innergroove tube | Φ7,innergroove tube | Φ7,innergroove tube | |
Outdoor fan motor | type | Propeller fan | Propeller fan | Propeller fan | Propeller fan | Propeller fan | |
Output | W | 25 | 25 | 25 | 25 | 55 | |
Capacitor | uF | 2.5 | 2.5 | 2.5 | 2.5 | 5 | |
Speed | r/min | 860 | 860 | 860 | 860 | 850 | |
Condenser | a.Number of rows | 1 | 1 | 1 | 1 | 1 | |
b.Tube pitch(a)x row pitch(b) | mm | 25×22 | 25×22 | 25×22 | 25×22 | 25×22 | |
c.Fin spacing | mm | 1.3-7U | 1.3-8U | 1.4-10U | 1.4-10U | 1.3-11U | |
d.Fin type | Louver Fin | Louver Fin | Louver Fin | Louver Fin | Louver Fin | ||
e.Tube outside dia.and type | mm | Φ7.94,innergroove tube | Φ7.94,innergroove tube | Φ7.94,innergroove tube | Φ7.94,innergroove tube | Φ7.94,innergroove tube | |
Connections | |||||||
Connecting Pipe | Gas | mm | Φ9(3/8'') | Φ9(3/8'') | Φ9(3/8'') | Φ9(3/8'') | Φ12(1/2'') |
Liquid | mm | Φ6(1/4'') | Φ6(1/4'') | Φ6(1/4'') | Φ6(1/4'') | Φ6(1/4'') | |
Connecting Wiring | Size x Core number | 3×1.0;2×0.75 | 3×1.0;2×0.75 | 3×1.5;2×0.75 | 3×1.5;2×0.75 | 3×1.5;2×0.75 | |
Others | |||||||
Suitable area | m2 | 10~15 | 15~20 | 15~23 | 15~23 | 25~35 | |
Max. refrigerant pipe length | m | 15 | 15 | 15 | 15 | 15 | |
Max. difference in level | m | 5 | 5 | 5 | 5 | 5 | |
Operation temperature range | ºC | 16~31 | 16~31 | 16~31 | 16~31 | 16~31 | |
Ambient temperature range | Outdoor | ºC | Cooling:15-43/Heating:-7-24 | Cooling:15-43/Heating:-7-24 | Cooling:15-43/Heating:-7-24 | Cooling:15-43/Heating:-7-24 | Cooling:15-43/Heating:-7-24 |
Indoor | ºC | Cooling:17-32/Heating:0-27 | Cooling:17-32/Heating:0-27 | Cooling:17-32/Heating:0-27 | Cooling:17-32/Heating:0-27 | Cooling:17-32/Heating:0-27 | |
Net dimensions (W x D x H) | Indoor | mm | 750*262*195 | 750*262*195 | 840*290*198 | 807*288*211 | 970*308*200 |
Outdoor | mm | 630*236*500 | 630*236*500 | 730*280*550 | 730*280*550 | 790*372*598 | |
Net weight | Indoor | kg | 7.5 | 7.5 | 8.5 | 8.5 | 10.5 |
Outdoor | kg | 24 | 25 | 30 | 30 | 35 | |
Packing dimensions (W x D x H) | Indoor | mm | 835*333*273 | 835*333*273 | 912*345*263 | 879*343*266 | 1035*378*278 |
Outdoor(w/i pipe) | mm | 760*348*525 | 760*348*525 | 847*371*602 | 847*371*602 | 941*412*663 | |
Gross weight | Indoor | kg | 8.5 | 8.5 | 9.5 | 9.5 | 11.5 |
Outdoor(w/i pipe) | kg | 29 | 30 | 35 | 35 | 41 | |
Loading Capacity w/i pipe | 40'HQ | 325 | 325 | 253 | 252 | 187 |
Precautions
- The outdoor unit must be installed firmly to reduce vibration and noise. There must be enough space in front of the suction and exhaust vents of the condenser for ventilation. If the wind is blocked, the condensation pressure will increase and it will cause shutdown;
- There should be no obstacles in front of the indoor unit, otherwise the wind will be affected;
When the air conditioner is running for rapid cooling, the selector switch can be adjusted to the high gear, and after the temperature drops, it can be adjusted to the medium-speed low gear;
- The ventilation switch can be used for the ventilation of the window air conditioner, but the ventilation time should not exceed 15 minutes;
- The outdoor unit of split type air conditioner cannot be inserted with sticks, otherwise the fan will be stuck or damaged
- After the air conditioner is stopped, it must be restarted after three minutes to protect the compressor;